Avolites Tiger Touch Operator's Manual Page 163

  • Download
  • Add to my manuals
  • Print
  • Page
    / 256
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 162
9. Cue Lists - Page 163
TitanUniversal_Man_v7-0_TT.doc 03 September 2013
The [Delay Out] setting of the cue would normally be used if
the console links automatically to the next cue, and sets a wait
time before the next cue starts its fade in. So the outgoing cue
would start to fade out, and the delay out time would run
before the new cue begins its fade in.
9.5.2 Cue linking & Link Offset
Cues in cue lists may be linked together, allowing you to build up
complex self-timed sequences. The link options are set using the
softkeys and are:
[Link Wait For Go]: the cue waits for the Go button to be
pressed then fires immediately. Link Offset is disabled.
[Link After Previous Cue]: The cue fires when the previous cue
has finished its delay in and fade in times. A Link Offset can be
set to add a delay between the previous cue finishing and this
cue firing. The offset can be given as a time in seconds, or as a
percentage of the fade time of the previous cue.
[Link With Previous Cue]: The cue fires at the same time as the
previous cue fires. A Link Offset can be set to add a delay
between the previous cue firing and this cue firing, set either in
seconds or as a percentage of the fade time of the previous
cue.
These options allow you to create complex self timed sequences by
building up simple steps. For example if you wanted the following
effect:
Go is pressed, fixture one starts fading up over 20s
After 10s fixture two fades up over 15s
Both lights stay on for 5s
Both lights go off in 3s
You could program
Cue 1 - Fixture 1 @ 100%, Fade In 20s, Link Wait For Go
Page view 162
1 2 ... 158 159 160 161 162 163 164 165 166 167 168 ... 255 256

Comments to this Manuals

No comments